XLW Prime OCS – 7″ COLOUR TOUCHSCREEN

Colour TFT Touchscreen with I/O, Serial Ports, CANBus and full Ethernet – All in One Product.

  • Logic engine features 1MB of application memory with a 0.02mS/K logic scan. Online Programming Mode (making logic changes on the fly without going thru stop mode) is supported. Operator Interface features include:
    • 800×480 LCD TFT color graphics display with a high resolution resistive touchscreen
    • USB 2.0 On-the-Go port (mini-B 5pin) is available for programming
    • USB 2.0 Host port (A) is available for exchanging files with USB FLASH drives
    • Two (2) RS-232 and one (1) RS-485 port support RTU/Modbus Master/Slave, ASCII In/Out, and PLC/Drive downloadable protocols

    Networking features include:

    • Built-in 10/100 Ethernet port
    • Integrated CsCAN port

    All units feature a microSD slot, supporting at least 32GB.

Compare

Overview

The XLW  Prime All-in-One controller with a built-in VGA TFT colour touchscreen, built-in I/O, networking options, removable Micro SD Card and USB ports.  It’s programmable by Horner APG’s industry recognised Cscape software and can control a wide range of different processes and machines from small to medium applications.  The XLW Prime comes fully equipped with 100Mbps Ethernet built into every model.  No additional Ethernet add-ons or accessories are needed. The XLW Prime Ethernet support includes an integrated Web Server, FTP Host, Email, Modbus/TCP Master/Slave, Programming and more.

The XLW  Prime includes both a USB Host port and a USB On-the-go Port – each at USB 2.0 speeds (480Mbps).  The Host Port allows connection of removable FLASH drives, supporting drives up to 2TB.  The On-the-go Port provides the fastest communications interface for Programme Change on Line (Online Change).  The eXLW I/O expansion is not limited to its Built-in I/O.

Specifications

CONTROLLER
Ladder Logic Memory 2 MB
Logic Scan Rate 0.02 mS/K
Removable Memory microSD
Local Comment Storage Yes
Floating Point Support Yes
AutoTune PID Capable Yes
OPERATOR INTERFACE
Characters / Pixels 800×480
Display Technology 7″ TFT Color
Character Height selectable fonts
Number of Pages 1023
Fields or Objects per Page 1023
Total Keys 6
OEM Faceplate Available Yes
I/O
Built-in I/O Points 22-44
SmartStix, SmartRail, SmartBlock I/O Support yes, CsCAN and Ethernet
Digital Inputs / Outputs, max 2048 / 2048
Analog Inputs / Outputs, max 512 / 512
General Purpose Registers (words) 50000
General Purpose Internal Coils (bits) 32768 (16384 retentive)
ETHERNET/INTERNET
Ethernet Support Standard, 1 Port
Remote Access WebMI, HTTP or EnvisionRV
Remote File Access FTP or EnvisionFX
IIoT Support MQTT (Sparkplug)
SERIAL COMMUNICATIONS
Total Active Ports 3
RS-232 Ports / RS-485 Ports 1 RS-232 & 1 RS-485 on first Modular Jack (MJ1/2); 1 RS-232 or RS-485 on second Modular Jack (MJ3)
PLC / Drive Protocols Yes
RTU / Modbus Master / Slave Yes
Serial ASCII In / Out Yes
USB Ports (A and Mini-B) USB 2.0 (480 MHz) for USB FLASH Drives (2TB); USB 2.0 (480 MHZ) Programming & Data Access
NETWORKING
Integrated CAN Networks 1
Supported CAN Networks CsCAN, CANopen, J1939 and DeviceNet Master (layer 3 as a selectable option)
Maximum CAN Distance 500m per segment, 4 segments maximum
Programming over CAN CsCAN only
PHYSICAL SPECIFICATIONS
Height 5.66″ / 144 mm
Width 7.34″ / 187 mm
Depth 1.84″ / 47 mm
I/O Module Depth COM option adds 0.98″ / 24.83 mm depth
OPERATING SPECS & STANDARDS
Operating Temperature* -0 to 60°C
Humidity (non-condensing) 5 to 95%
Product Certifications/Approvals UL Class 1 Div II, CE
Environmental Rating UL Type 1, 3R, 4, 4x, 12, 12k, 13

Downloads

XLW Prime Sales sheet Download
XL Prime Series Accordion Brochure Download
XL Prime Series Presentation Download
Technical Documentation (Requires Login/Registration)
XLW Prime User Manual Download
XLW Prime Model 0 Datasheet Download
XLW Prime Model 2 Datasheet Download
XLW Prime Model 3 Datasheet Download
XLW Prime Model 4 Datasheet Download
XLW Prime Model 5 Datasheet Download
XLW Prime Model 6 Datasheet Download

On-Board I/O

Selection Table

Model DC In DC Out Relays HS In HS Out mA/V In mA/V RTD/T mA/V Out
HEXP381C100
HEXP381C112 12 6 4 4
HEXP381C113 12 12 4 2 2
HEXP381C114 24 16 4 2 2
HEXP381C115 12 12 4 2 2 2
HEXP381C116 12 12 4 2 6 4

There are 4 high-speed inputs of the total DC Inputs. There are 2 high-speed outputs of the total DC outputs. Model 2, 3 & 4 feature 12-bit Analogue I/O. Model 5 features 14/16-bit Analogue I/O. High-speed Outputs can be used for PWM and Pulse Train Outputs, currently limited to <65 kHz. Model 6 Features a 14/17 bit Analogue I/O.

HIGH-SPEED INPUTS

Number of Counters 2
Maximum Frequency 500 kHz each
Accumulator Size 32-bits each
Modes Supported Totalizer, quadrature, pulse measurement, frequency measurement, set-point controlled outputs
HIGH-SPEED OUTPUTS
Modes Supported Stepper, PWM
I/O Support
Build in I/O Yes
SmartStack I/O Yes via CsCAN
SmartStix I/O Yes via CsCAN
SmartMod I/O Yes via Modbus Serial
FOX Expansion I/O No

Built-In Expansion I/O

 

 

XDAC 2 channel analog output I/O option kit

 

 

 

 

 

XDAC 4 channel analog output I/O option kit

 

 

add on interface

 

 

Add-on Interface Kits

Remote I/O

Ethernet Based I/O
CsCAN Based I/O
CANopen Based I/O
Modbus RTU Based I/O

Networking

Integrated CAN Networks 1
Supported CAN Networks CsCAN, CANopen, DeviceNet Master, J1939
Supported Ethernet Protocols TCP/IP, Modbus TCP, FTP, SRTP, EGD, ICMP, ASCII

NTP (Network Time Protocol) allowing synchronisation of internet based Horner controllers to a centralised web based time server

WebMI Published directly from the Horner Controller, WebMI allows plant data to be monitored and controlled from your computer, tablet or other mobile device

Certifications

CE Certified Download
ROHS & WEEE Compliance statement – July 01,2018 Download
UL Certification Download