Horner Canvas Series and OCS I/O

Horner Canvas Series - Coming soon

cancas

The release of Cscape 10 will also unlock the full potential of our upcoming Canvas Series of controllers. The Canvas Series will harness all the above features on a range of powerful All-In-One controllers to suit all kinds of applications.

The Canvas Series Controllers will feature:

  • All-new Models with a New Look
  • Multi-core CPU with an Advanced Graphics Engine

Please note that the Canvas Series will require Cscape 10.

Cscape 10 and Canvas Series controllers are currently scheduled to be released in 2023.

Please do not hesitate to email our Tech Support team should you have any questions.

Canvas Series Models

Canvas Series Controller Part Numbers Similar to (for reference)
Canvas 3.5C HE-CV-035C-A00 XL4
HE-CV-035C-A02
HE-CV-035C-A03
HE-CV-035C-A04
HE-CV-035C-A05
HE-CV-035C-A06
Canvas Series Controller Part Numbers Similar to (for reference)
Canvas 4.5C HE-CV-043C-A01 X5
Canvas Series Controller Part Numbers Similar to (for reference)
Canvas 7C HE-CV-070C-A00 EXLW
HE-CV-070C-A02
HE-CV-070C-A03
HE-CV-070C-A04
HE-CV-070C-A05
HE-CV-070C-A06
Canvas Series Controller Part Numbers Similar to (for reference)
Canvas 7D HE-CV-070D-A00 XL7
HE-CV-070D-A02
HE-CV-070D-A03
HE-CV-070D-A04
HE-CV-070D-A05
HE-CV-070D-A06
Canvas Series Controller Part Numbers Similar to (for reference)
Canvas 10.1D HE-CV101D-A00 X10
HE-CV101D-A02
HE-CV101D-A03
HE-CV101D-A04
HE-CV101D-A05
HE-CV101D-A06
Canvas Series Controller Part Numbers Similar to (for reference)
Canvas 15D HE-CV150D-A00 XL15+ (historically called XL+)
HE-CV150D-A02
HE-CV150D-A03
HE-CV150D-A04
HE-CV150D-A05
HE-CV150D-A06

Please note: All above information about the Canvas Series is subject to change

Cscape 10 is our next major release for our free PLC software. Cscape combines graphical ladder diagram programming (based on IEC-1131) with operator interface development to completely integrate the control package.

Included in this major release we will have:

  • Feature-rich Graphics
  • Re-Designed user interface
  • New and improved symbol library
  • Improved ease of use with gesture support, including rotate, flip and swipe gestures
  • Interactive Trend Object
  • High Quality Control Panel Visualization and Objects
  • Superior Animation Performance
  • Continued Evolution of Advanced Logic Languages

The release of Cscape 10 will also unlock the full potential of our upcoming Canvas Series of controllers. The Canvas Series will harness all the above features on a range of powerful All-In-One controllers to suit all kinds of applications.

The Canvas Series Controllers will feature:

  • All-new Models with a New Look
  • Multi-core CPU with an Advanced Graphics Engine

Please note that the Canvas Series will require Cscape 10.

Cscape 10 and Canvas Series controllers are scheduled to be released in 2023.

Please do not hesitate to email our Tech Support team should you have any questions.

OCS I/O: Highly Expandable & Flexible Remote I/O for OCS

Maybe You Only Need One More…

Sometimes you only need a little bit. Start with the CNX116 – which includes I/O right on the base. Meant as the perfect small amount of complementary I/O, the CNX116 gives you (2) Flexible Inputs (Digital or 12-bit Analog), (2) Digital Outputs, (1) 16-bit Universal Analog Input and (1) 12-bit Analog Output right onboard. Two inputs that can be used for either digital or analog signals, giving it up to 3 analog inputs without even needing another module.

…Or Maybe You Need A Lot

With expandability up to 7 modules per base and 16 bases per network, OCSI/O can handle almost any amount of I/O needs. It even includes a CsCAN In and CsCAN Out port to allow you to easily daisy-chain multiple bases without requiring a lot of custom wiring.

and Configuration Is a Breeze

Whether it’s a little or a lot, OCS-I/O configuration is meant to be simple and effortless. It’s configured using Cscape software, so when wired up, it can find the base and autopopulate all installed modules automatically. From there you may only need to tweak a couple of configurations for the base or modules to be ready to go. Cscape also calculates the I/O power usage for you automatically, so you’ll never overload an I/O base.

ADU100

Analog Inputs 4
Resolution 16-bit
Supported Input Types RTD/TC/0-20mA/0-10V
Thermocouple Types J/K/T/E/N/R/S
RTD Types PT100, PT1000
Max Error at 25ºC 0.2%
Operating Air Temp -40ºC to 60ºC

DAC107

Analog Inputs 4
Resolution 12-bit
Output Ranges 0-20mA/4-20mA/ +/-10V
Minimum 10V Load 500Ω
Maxmum Current Load 500Ω
Max Error at 25ºC 0.2%
Operating Air Temp -40ºC to 60ºC

DIM620

AC Inputs 8
Commons per Module 1
Input Voltage Range 90 to 240VAC
Absolute Max Voltage 260 VAC
OFF to ON Response <20ms
ON to OFF Response <20ms
Operating Air Temp -40ºC to 60ºC

DIQ512

Digital Inputs 4
Input Voltage Range 12 to 24 VDC
Commons per Module 4
Relay Outputs 4
Max Output Voltage 120VAC
Max Output Current 3A each
Operating Air Temp -40ºC to 60ºC

DIQ616

DC Inputs 8
Input Voltage Range 12 to 24 VDC
Input Commons 1
DC Outputs 8
Absolute Max Voltage 32DC
Output Commons 1
Operating Air Temp -40ºC to 60ºC

DIQM502

Relay Outputs 4
Max Current per Relay 8A AC / 5A DC
Max Total Current 16A
Max Output Voltage 240VAC
Expected Life 100K @ Rated Load
Operating Air Temp -40ºC to 60ºC

CNX116

Max Number of Modules  7 per base
Flexible Inputs 2 (Digital or Analog)
Input Voltage Range 5V, 12V or 24V
Analog Input Types 0-20mA/4-20mA/0-10V
DC Outputs 2 (2A)
Output Voltage Range 10 to 30 VDC
Operating Air Temp -40ºC to 60ºC
Universal Analog In 1
Input Resolution 16-bit
Supported Input Types RTD/TC/0-20mA/0-10V
Max Error at 25ºC 0.2%
Analog Outputs 1
Output Resolution 12-bit
Output Ranges 0-20mA/4-20mA/0-10V

CNX116 Base

Flexible Inputs Digital or Analog DC Outputs Universal Analog Inputs Analog Outputs
2* 2 1 1

*I1 and I2 can be configured as either digital or analog inputs

Part Numbers

OCS-I/0 Ac Inputs DC Inputs Relay Outputs DC Outputs Universal Analog Inputs Analog Outputs
HE959ADU100 0 0 0 0 4 0
HE959DAC107 0 0 0 0 0 4
HE959DIM620 8 0 0 0 0 0
HE959DIQ512 0 4 4 0 0 0
HE959DIQ616 0 8 0 8 0 0
HE959DQM502 0 0 4 0 0 0

Please note: All above information about the OCS I/O is subject to change

Request more information